U.S. flag

An official website of the United States government, Department of Justice.

NCJRS Virtual Library

The Virtual Library houses over 235,000 criminal justice resources, including all known OJP works.
Click here to search the NCJRS Virtual Library

Validation of Walkway Tribometers: Establishing a Reference Standard

NCJ Number
230717
Journal
Journal of Forensic Sciences Volume: 55 Issue: 2 Dated: March 2010 Pages: 366-370
Author(s)
Christopher M. Powers, Ph.D., P.T.; Mark G. Blanchette, M.S.; John R. Brault, M.S.; Jim Flynn, P.E.; Gunter P. Siegmund, Ph.D., P.Eng.
Date Published
March 2010
Length
5 pages
Annotation
Tribometers are mechanical devices used to measure walkway coefficient of friction (COF) for the purpose of assessing slip risk. The purpose of this study was to define a tribometer reference standard and use it to assess the performance of various tribometers.
Abstract
Eighty subjects were randomly assigned to walk across one of four wet walkway surfaces (polished black granite, porcelain, vinyl composition tile, and ceramic tile) to establish the relative slipperiness of each surface. Eleven tribometers were subsequently used to measure and rank the COF of all four surfaces. Our results revealed that only four of the 11 tribometers (Wessex pendulum, Sigler pendulum, Mark II, and Mark III) met our compliance criteria by both correctly ranking all four surfaces and differentiating between surfaces of varying degrees of slipperiness. Our protocol demonstrates that human gait-based measures of slipperiness can be used to create reference standards against which tribometer measurements can be validated. Tables and references (Published Abstract)

Downloads

No download available

Availability