The Predictive Power of SIMION/SDS Simulation Software for Modeling Ion Mobility Spectrometry Instruments

NCJ Number
310094
Journal
International Journal of Mass Spectrometry Volume: 276 Issue: 1 Dated: September 2008 Pages: 1-8
Author(s)
Hanh Lai; Timothy R. Mcjunkin; Carla J. Miller; Jill R. Scott; José R. Almirall
Date Published
September 2008
Length
8 pages
Annotation

This paper reports on a study that incorporated an external programming code that compiled within SIMION to consider the collision effect of neutrals on ions; it discusses the simulation of an actual commercial ion mobility spectrometer, the challenges of using SIMION/SDS, and the comparison of the authors’ proposed model with experimental data under various IMS instrumental conditions.

Abstract

The combined use of SIMION 7.0 and the statistical diffusion simulation (SDS) user program in conjunction with SolidWorks® with COSMSOSFloWorks® fluid dynamics software to model a complete, commercial ion mobility spectrometer (IMS) was demonstrated for the first time and compared to experimental results for tests using compounds of immediate interest in the security industry (e.g., 2,4,6-trinitrotoluene, 2,7-dinitrofluorene, and cocaine). The effort of this research was to evaluate the predictive power of SIMION/SDS for application to IMS instruments. The simulation was evaluated against experimental results in three studies: (1) a drift:carrier gas flow rates study assesses the ability of SIMION/SDS to correctly predict the ion drift times; (2) a drift gas composition study evaluates the accuracy in predicting the resolution; (3) a gate width study compares the simulated peak shape and peak intensity with the experimental values. SIMION/SDS successfully predicted the correct drift time, intensity, and resolution trends for the operating parameters studied. Despite the need for estimations and assumptions in the construction of the simulated instrument, SIMION/SDS was able to predict the resolution between two ion species in air within three percent accuracy. The preliminary success of IMS simulations using SIMION/SDS software holds great promise for the design of future instruments with enhanced performance. (Published Abstract Provided)