HPLC (High-Performance Liquid Chromatography) Method Using Absorbance Ratioing for the Identification of Diamorphine in Illicit Heroin Samples

NCJ Number
109509
Journal
Forensic Science International Volume: 37 Issue: 1 Dated: (March 1988) Pages: 55-66
Author(s)
P C White; A Etherington; T Catterick
Date Published
1988
Length
12 pages
Annotation
A high-performance liquid chromatography (HPLC) method is described for the identification of diamorphine in illicit heroin samples.
Abstract
Diamorphine is identified through a combination of absorbance ratios and retention time data. These data are obtained with a linear diode array (LDA) multiwavelength detector. Absorbance ratios remain constant from 50 nanograms to 2.3 micrograms of diamorphine injected, and the method is rapid and requires minimal operator involvement. (Publisher abstract)