Annotation
Equipment for annealing casework sized glass particles is described.
Abstract
Investigations were carried out using a simple muffle furnace, a temperature programmed furnace and a metal sample holder. Because they produced a uniform and reproducible thermal environment, best results were obtained from a comvinatrion of the temperature programmed furnace and the metal sample holder. Refractive index changes for window and toughened glass specimens were investigated and a simple, reproducible annealing routine for casework was devised. (Publisher abstract)