This is the Final Report on the findings and methodology of a research project with the goal of improving the value of glass-evidence analysis by developing objective and quantitative interpretation guidelines for the evaluation and reporting of glass-evidence analysis results.
The project first focused on the development of a reporting scheme based on previously reported likelihood ratio calculation by Aitken and Lucy, in conjunction with a "calibration" step previously reported by Ramos. The goal of this first part of the project was to develop a database derived from the analysis of glass using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Typically, a match criterion is used to compare the known and questioned sample; however, match criteria have several disadvantages that can be overcome with an alternative approach. This approach is the likelihood ratio (LR). Two LA-ICP-MS glass databases were used to evaluate the performance of the LR. These were a vehicle windshield database (420 samples) and a casework database (385 samples). Compared to the match criterion, the LR achieved improved false exclusion rates and produced similar false inclusion rates. In addition, the LR limited the magnitude of the misleading evidence, providing only weak support for the incorrect proposition. The LR was also tested in a series of three inter-laboratory studies. Good correct association rates (94-100 percent) were obtained for same-source samples for all three inter-laboratory exercises. All different-source samples were correctly excluded with the LR. 3 tables, 1 figure, and 52 references
Downloads
Similar Publications
- Forensic Discrimination of Dyed Hair Color: I. UV-Visible Microspectrophotometry
- Utilizing Derivatizing Agents for the Differentiation of Cannabinoid isomers in Complex Food, Beverage and Personal-care Product Matrices by Ambient Ionization Mass Spectrometry
- Sex Estimation Using Metrics of the Innominate: A Test of the DSP2 Method