U.S. flag

An official website of the United States government, Department of Justice.

NCJRS Virtual Library

The Virtual Library houses over 235,000 criminal justice resources, including all known OJP works.
Click here to search the NCJRS Virtual Library

Automated Extraction of DNA From Biological Stains on Fabric From Crime Cases. A Comparison of a Manual and Three Automated Methods

NCJ Number
246391
Journal
Forensic Science International: Genetics Volume: 7 Issue: 3 Dated: May 2013 Pages: 384-388
Author(s)
Michael Stangegaard; Benjamin B. Hjort; Thomas N. Hansen; Anders Hoflund; Helle S. Mogensen; Anders J. Hansen; Niels Morling
Date Published
May 2013
Length
5 pages
Annotation
DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA.
Abstract
The presence of PCR inhibitors in extracted DNA may interfere with the subsequent quantification and short tandem repeat (STR) reactions used in forensic genetic DNA typing. DNA extraction from fabric for forensic genetic purposes may be challenging due to the occasional presence of PCR inhibitors that may be co-extracted with the DNA. Using 120 forensic trace evidence samples consisting of various types of fabric, researchers compared three automated DNA extraction methods based on magnetic beads (PrepFiler Express Forensic DNA Extraction Kit on an AutoMate Express, QIAsyphony DNA Investigator kit either with the sample pre-treatment recommended by Qiagen or an in-house optimized sample pre-treatment on a QIAsymphony SP) and one manual method (Chelex) with the aim of reducing the amount of PCR inhibitors in the DNA extracts and increasing the proportion of reportable STR-profiles. A total of 480 samples were processed. The highest DNA recovery was obtained with the PrepFiler Express kit on an AutoMate Express while the lowest DNA recovery was obtained using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen. Extraction using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen resulted in the lowest percentage of PCR inhibition (0 percent) while extraction using manual Chelex resulted in the highest percentage of PCR inhibition (51 percent). The largest number of reportable STR-profiles was obtained with DNA from samples extracted with the PrepFiler Express kit (75 percent) while the lowest number was obtained with DNA from samples extracted using a QIAsymphony SP with the sample pre-treatment recommended by Qiagen (41 percent). (Published Abstract)